Evaporative Water Consumption in Greenhouse Cooling: A Mass-Balance Model for Arid, Semi-Arid, and Humid Mediterranean Climates

  • ahamed Abdalla Makauy Abass Department of Agricultural Engineering, Faculty of Agricultural Technology and Fish Science, Engineering, University of Elneelain, Khartoum, Sudan
  • A. Nafi BAYTORUN Department of Agricultural Structures and Irrigation, Faculty of Agriculture, University of Çukurova, Turkey
  • Osama Osman Ali Department of Agricultural Engineering, Faculty of Agricultural Technology and Fish Science, Engineering, University of Elneelain, Khartoum, Sudan

الملخص

Water scarcity in arid and semi-arid agricultural regions necessitates optimization of greenhouse evaporative cooling systems. The study develops a validated psychrometric model for quantifying water requirements in fan-and-pad cooling systems across Mediterranean humid, semi-arid, and continental temperate climates. The study shows that water consumption increases linearly with ventilation rate (R² = 0.98), but cooling effectiveness plateaus once the set-point temperature is achieved. At 205 m³ m⁻² h⁻¹ and 38 °C, water demand varied 2.3-fold among climate zones: 1.57 kg m⁻² h⁻¹ (arid, D = 6.1 kPa), 1.34 kg m⁻² h⁻¹ (semi-arid, D = 5.8 kPa), and 0.70 kg m⁻² h⁻¹ (humid, D = 3.3 kPa), with corresponding cooling of 13.0°C, 9°C, and 2.9°C. Beyond minimum airflow requirements, each additional 20 m³ m⁻² h⁻¹ increased water use by 0.12 kg m⁻² h⁻¹ without further temperature reduction, indicating that simply increasing ventilation rate will increase water consumption to a point where no further temperature change occurs. Climate conditions govern the effectiveness of efficiency improvements. Pad efficiency upgrades yield diminishing returns in humid regions but substantial savings in arid environments, with investments economically justified only where vapor pressure deficit exceeds 4.5 kPa. Specifically, improving pad efficiency from 80% to 90% saved 20.7% water in semi-arid conditions, 6.6% in humid conditions, and only 1.5% in continental temperate conditions. It was concluded that A design nomogram enables direct water requirement estimation from vapor pressure deficit. The study provides empirical relationships for climate-specific system design and dynamic ventilation control, validated against eight published studies

المراجع

Abdel-wahab, S. K. (1994). Energy and water management in evaporative cooling systems in Saudi Arabia. Resources, Conservation and Recycling, 12(3–4), 135–146.
Al-Helal, I. M. (2007). Effects of ventilation rate on the environment of a fan-pad evaporatively cooled, shaded greenhouse in extreme arid climates. Applied Engineering in Agriculture, 23(2), 221–230.
Al-Ismaili, A. M., & Al-Azri, N. A. (2016). Evaluation of a pad fan greenhouse system in Oman: Water consumption and cropping performance. International Journal of Vegetable Science, 22(6), 599–616. https://doi.org/10.1080/19315260.2016.1180595
Al-Massoum, A., Haffar, I., & Mahmoud Ahmed, H. (1997). A similitude model for testing greenhouse evaporative cooling pads under the hot-arid conditions of the UAE. II Modelling Plant Growth, Environmental Control and Farm Management in Protected Cultivation, 456, 329–338.
Alduchov, O. A., & Eskridge, R. E. (1996). Improved Magnus form approximation of saturation vapor pressure. Journal of Applied Meteorology, 35(4), 601–609.
Arbel, A., Yekutieli, O., & Barak, M. (1999). Performance of a fog system for cooling greenhouses. Journal of Agricultural and Engineering Research, 72(2), 129–136. https://doi.org/10.1006/jaer.1998.0351
Baytorun, A. N. (2016). Seralar, sera tipleri, donanımı ve iklimlendirilmesi. Nobel Akademik Yayıncılık.
Baytorun, A. N., Mahamed, A., & Makauy, A. (2019). Farklı İklim Bölgelerindeki Seralarda Evaporatif Soğutma Olanaklarının Belirlenmesi [Determination of evaporative cooling possibilities in greenhouses in different climate regions]. 34(December), 29–38.
Baytorun, A. N., & Zaimoglu, Z. (2018). Climate control in Mediterranean greenhouses. In Climate resilient agriculture—Strategies and perspectives (pp. 89–114). https://doi.org/10.5772/intechopen.72367
Boulard, T., & Baille, A. (1993). A simple greenhouse climate control model incorporating effects of ventilation and evaporative cooling. Agricultural and Forest Meteorology, 65(3–4), 187–205.
Djibrilla, A. S. M., Rabani, A., Illyassou, K. M., Abdoulkader, A. H., & Al-Maslami, M. S. M. (2024). Improving the sustainability and effectiveness of photovoltaic evaporative cooling greenhouse in the Sahel. Scientific Reports, 14, 11255. https://doi.org/10.1038/s41598-024-61878-5
Franco, A., Valera, D. L., & Peña, A. (2014). Energy efficiency in greenhouse evaporative cooling techniques: Cooling boxes versus cellulose pads. Energies, 7(3), 1427–1447. https://doi.org/10.3390/en7031427
Ghanem, M. I. H., El-Shazly, M. A., Kishta, A. M., Abdeen, M. A. M., & Awny, A. (2025). Performance evaluation of a sustainable evaporative cooling system using a cooling pad based on agricultural residues. Zagazig Journal of Agricultural Research, 52(5), 1085–1102.
Hegazy, A., Farid, M., Subiantoro, A., & Norris, S. (2022). Sustainable cooling strategies to minimize water consumption in a greenhouse in a hot arid region. Agricultural Water Management, 274, 107960. https://doi.org/10.1016/j.agwat.2022.107960
Jongebreur, A. A. (2000). Strategic themes in agricultural and bioresource engineering in the 21st century. Journal of Agricultural Engineering Research, 76(3), 227-236.
Junpayap, W., Treeamnuk, T., & Treeamnuk, K. (2024). Temperature and relative humidity control in a greenhouse evaporative cooling-pad system. RMUTP Science Journal.
Kittas, C., Katsoulas, N., & Baille, A. (2008). Energy and water balance of a greenhouse with an evaporative cooling system. Acta Horticulturae, 2008.
Kittas, C., Katsoulas, N., Bartzanas, T., & Bakker, J. C. (2013). Greenhouse climate control and energy use. In Good agricultural practices for greenhouse vegetable crops: Principles for Mediterranean climate areas (pp. 63–95).
Kubota, C., Sabeh, N. C., & Giacomelli, G. A. (2006). Water use for pad and fan evaporative cooling of a greenhouse in a semi-arid climate. International Symposium on Greenhouse Cooling, 719, 409–416.
Kumar, S., Salins, S., Reddy, S., & Nair, P. (2021). Comparative performance analysis of a static & dynamic evaporative cooling pads for varied climatic conditions. Energy, 233, 121136. https://doi.org/10.1016/j.energy.2021.121136
Mahmood, D. M. N., Aljubury, I. M. A., Al Maimuri, N. M. L., Al-Obaidi, M. A., Rashid, F. L., & Al-Musawi, M. H. (2025). Experimental evaluation of a hybrid evaporative and groundwater cooling system for enhancing photovoltaic efficiency in arid climates. Scientific Reports, 15, 35571. https://doi.org/10.1038/s41598-025-97087-5
Montero, J. I. (2006). Evaporative cooling in greenhouses: Effect on microclimate, water use efficiency and plant response. International Symposium on Greenhouse Cooling, 719, 373–384.
26. Murray, F. W. (1967). On the computation of saturation vapor pressure. Journal of Applied Meteorology, 6(1), 203–204.
Sabeh, N. (2007). Evaluating and minimizing water use by greenhouse evaporative cooling systems in a semi-arid climate [Doctoral dissertation, University of Arizona].
Sabeh, N. C., Giacomelli, G. A., & Kubota, C. (2006). Water use by greenhouse evaporative cooling systems in a semi-arid climate. 2007 ASAE Annual Meeting, 1.
Salman, A. H., Jasim, J. A., Alwan Aljuboori, M. K., & Zaidan, A. A. (2024). Efficiency analysis of a two-stage evaporative cooling system with sustainable water pad. International Journal of Heat and Technology.
Tetens, O. (1930). Über einige meteorologische Begriffe. Zeitschrift für Geophysik, 6, 297–309.
Tsafaras, I., Campen, J. B., Stanghellini, C., Zwart, H. F. De, Voogt, W., Scheffers, K., Al Harbi, A., & Al Assaf, K. (2021). Intelligent greenhouse design decreases water use for evaporative cooling in arid regions. Agricultural Water Management, 250, 106807. https://doi.org/10.1016/j.agwat.2021.106807
Velasco-g, E., Tejero-gonz, A., Jorge-rico, J., & Rey-mart, F. J. (2020). Experimental investigation of the potential of a new fabric-based evaporative cooling pad. Journal of Agricultural Engineering Research.
Von Zabeltitz. (2011). Integrated Greenhouse Systems for Mild Climates: Climate Conditions, Design, Construction, Maintenance, Climate Control. Springer.
منشور
2026-10-20
كيفية الاقتباس
ABASS, ahamed Abdalla Makauy; BAYTORUN, A. Nafi; OSMAN ALI, Osama. Evaporative Water Consumption in Greenhouse Cooling: A Mass-Balance Model for Arid, Semi-Arid, and Humid Mediterranean Climates. المجلة الزراعية, [S.l.], v. 22, n. 1, oct. 2026. ISSN 1728-9556. متوفر في: <http://journals.uofg.edu.sd/index.php/gjas/article/view/2647>. تأريخ الوصول: 23 nov. 2026.
القسم
Articles